Rapid HVAC Products
email
2000 Overview
2000 Features and Benefits
2000 Tech Data
2000 Applcations
8500 Literature

RAPID™ Indirect-Fired Air Handling 8500 Series
Technical Data


Discharge Options

Horizontal Unit/Horizontal Discharge
Upright Unit/Top Left Discharge
Upright Unit/Bottom Left Discharge
Horizontal Unit/Bottom Discharge
Upright Unit/Top Right Discharge
Upright Unit/Bottom Right Discharge
Horizontal Unit/Top Discharge
Upright Unit/Top Discharge
Upright Unit/Bottom Discharge
LEGEND
OA=Outside Air
DA=Discharge Air
RA=Return Air


Output

Model
34
45
50
65
75
85
100
125
150
CFM
3,500-6,000
3,500-6,000
4,000-8,000
4,000-8,000
6,000-12,000
6,000-12,000
6,000-12,000
10,000-18,000
13,000-24,000
Output [MBH]*
240-350
240-450
240-500
520-650
520-750
520-850
520-1,000
560-1,250
560-1,500

Model
175
200
225
250
275
300
350
400
450
CFM
13,000-24,000
21,000-37,000
21,000-37,000
21,000-45,000
21,000-45,000
30,000-45,000
35,000-57,000
35,000-57,000
35,000-57,000
Output [MBH]*
600-1,750
600-2,000
600-2,250
600-2,500
720-2,750
720-3,000
720-3,500
1,400-4,000
1,400-4,500
*1 MBH=1,000 Btu/h


Installation Code and Annual Inspections:
All installations and service of RAPID™ equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Rapid Engineering and conform to all requirements set forth in the Rapid Engineering manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Rapid Engineering recommends that a qualified contractor annually inspect your RAPID™ equipment and perform service where necessary, using only replacement parts sold and supplied by Rapid Engineering.

Further Information:
Applications, engineering and detailed guidance on systems design, installation and product performance is available through RAPID™ representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.

This product is not for residential use.

This document is intended to assist licensed professionals in the exercise of their professional judgement.

Direct-Fired Air Handling UnitsAir TurnoverLow Intensity Infrared HeatersAxial Fan Unit HeaterIndirect-Fired Air HandlerGas Fired Warm Air or Forced AirMake-Up AirFixed RecirculationAir ManagementHeatingCoolingBuilding PressurizationAir CirculationEvaporation

©Rapid Engineering 2008 Terms & Conditions